Designed specifically for energy conscious customers like you, the Fluke 1730 Three-Phase Electrical Energy Logger introduces a new simplicity to discovering sources of electrical energy waste. Profiling energy usage across your facility helps you identify opportunities for energy savings and provides you with the easy-to-understand data required for you to take the right action.

    Error: Contact form not found.

    • Key measurements: Voltage, current, power, power factor and associated values enable you to optimize and implement your energy saving strategies.
    • Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display.
    • Comprehensive logging: More than 20 separate logging sessions can be stored on the instrument. In fact, all measured values are automatically logged and can be reviewed during logging and before downloading for on-the-go analysis.
    • Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function.
    • Complete “in-the-field” setup through the front panel: no need to return to the workshop for download and setup or to take a computer to the electrical panel.
    • Wide range power: power instrument directly from the measured circuit eliminating the need to find a power outlet while allowing the instrument to be secured safely inside electrical panels.
    • Two USB ports: one for PC connection and another for fast, simple download to standard USB thumb drives, or other USB devices.
    • Compact size: designed to fit in tight spaces and panels.
    • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream.
    • Optimized measurement accessories: flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.
    • Battery life: four-hour operating time (backup time) per charge on lithium-ion battery.
    • Security: We safeguard your best asset from theft with a hefty, durable Kensington lock.
    • Energy analyze application software: Download and analyze a snapshot of your energy savings potential with our automated reporting.
    Specifications
    Accuracy
    Parameter Range Resolution Intrinsic Accuracy at Reference Conditions (% of Reading + % of Full Scale)
    Voltage 1000 V 0.1 V ± (0.2 % + 0.01 %)
    Current: Direct input iFlex1500-12 150 A 0.1 A ± (1 % + 0.02 %)
    1500 A 1 A
    iFlex3000-24 300 A 1 A ± (1 % + 0.02 %)
    3000 A 10 A
    iFlex6000-36 600 A 1 A ± (1.5 % + 0.03 %)
    6000 A 10 A
    i40s-EL clamp 4 A 1 mA ± (0.7 % + 0.02 %)
    40 A 10 mA
    Frequency 42.5 Hz to 69 Hz 0.01 Hz ± (0.1 %)
    Auxillary input ± 10 V dc 0.1 mV ± (0.2 % + 0.02 %)
    Voltage min/max 1000 V 0.1 V ± (1 % + 0.1 %)
    Current min/max defined by accessory defined by accessory ± (5 % + 0.2 %)
    Cosφ/DPF 0 <= Cosφ <=1 0.01 ± 0.025
    Power factor 0 <= PF <=1 0.01 ± 0.025
    THD on voltage 1000 % 0.1 % ± (2.5 % ± 0.05)
    THD on current 1000 % 0.1 % ± (2.5 % ± 0.05)

     

    Intrinsic Uncertainty ± (% of reading + % of range)1
    Parameter Influence quantity iFlex1500-12 iFlex3000-24 iFlex6000-36 i40S-EL
    150A/1500A 300A/3000A 600/6000A 4A/40A
    Active power P PF ≥ 0.99 1.2 % + 0.005 % 1.2 % + 0.0075 % 1.7 % + 0.0075 % 1.2 % + 0.005 %
    0.5 < PF < 0.99 1.2 % + 7 x (1-PF) +0.005 % 1.2 % + 7 x (1-PF) + 0.0075 % 1.7 % + 7 x (1-PF) + 0.0075 % 1.2 % + 10 x (1-PF) + 0.005 %
    Apparent power S, S fund. 0 ≤ PF ≤ 1 1.2 % + 0.005 % 1.2 % + 0.0075 % 1.7 % + 0.0075 % 1.2 % + 0.005%
    Reactive power N, Q fund. 0 ≤ PF ≤ 1 2.5 % of measured apparent power
    Additional uncertainty in % of range1 U >250 V 0.015 % 0.0225 % 0.0225 % 0.015 %
    1Range = 1000 V x Irange
    Reference conditions:
    Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %
    Input conditions: Cosφ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %
    Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V
    Input current: I > 10 % of Irange
    Primary conductor of clamps or Rogowski coil in center position
    Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

     

    Electrical Specifications
    Power Supply
    Voltage range 100 V to 500 V using safety plug input when powering from the measurement circuit
    100 V to 240 V using standard power cord (IEC 60320 C7)
    Power consumption Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
    Efficiency ≥ 68.2 % (in accordance with energy efficiency regulations)
    Maximum no-load consumption < 0.3 W only when powered using IEC 60320 input
    Mains power frequency 50/60 Hz ± 15 %
    Battery Li-ion 3.7 V, 9.25 Wh, customer-replaceable
    On-battery runtime Four hours in standard operating mode, up to 5.5 hours in power saving mode
    Charging time < 6 hours
    Data Acquisition
    Resolution 16-bit synchronous sampling
    Sampling frequency 5120 Hz
    Input signal frequency 50/60 Hz (42.5 to 69 Hz)
    Circuit types 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ
    Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies)
    THD THD for voltage and current is calculated using 25 harmonics
    Averaging period User selectable 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
    Demand interval User selectable 5 min, 10 min, 15 min, 20 min, 30 min
    Data storage Internal flash memory (not user replaceable)
    Memory size Typical 20 logging sessions of 10 weeks with 10-minute intervals¹
    Logging period Averaging period
    Recommended
    20 sessions 1 session
    1 second 3 hours 2.5 days
    5 seconds 15 hours 12 days
    10 seconds 28 hours 24 days
    30 seconds 3.5 days 10 weeks
    1 minute 7 days 20 weeks
    5 minutes 5 weeks 2 years
    10 minutes 10 weeks > 2 years
    15 minutes 3.5 months > 2 years
    30 minutes 7 months > 2 years¹
    Interfaces
    USB-A File transfer via USB flash drive, firmware updates
    Max. current: 120 mA
    USB-mini Data download device to PC
    Extension port Accessories
    Voltage Inputs
    Number of inputs 4 (3 phases and neutral)
    Maximum input voltage 1000 Vrms, CF 1.7
    Input impedance 10 MΩ
    Bandwidth (-3 dB) 2.5 kHz
    Scaling 1:1, 10:1, 100:1, 1000:1 and variable
    Measurement category 1000 V CAT III/600 V CAT IV
    Current Inputs
    Number of inputs 3, mode selected automatically for attached sensor
    Input voltage Clamp input: 500 mVrms/50 mVrms; CF 2.8
    Rogowski coil input 150 mVrms / 15 mVrms at 50 Hz, 180 mVrms / 18 mVrms at 60 Hz; CF 4; all at nominal probe range
    Range 1 A to 150 A/10 A to 1500 A with thin iFlex flexible current probe, 12 inches
    3 A to 300 A/30 A to 3000 A with thin iFlex flexible current probe, 24 inches
    6 A to 600 A/60 A to 6000 A with thin iFlex flexible current probe, 36 inches
    40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
    Bandwidth (-3 dB) 1.5 kHz
    Scaling 1:1 and variable
    Auxiliary Inputs
    Number of inputs 2
    Input range 0 to ± 10 V dc, 1reading/s
    Scale factor (available 2014) Format: kx + d user configurable
    Displayed units (available 2014) User configurable (7 characters, for example, °C, psi, or m/s)
    1. The number of possible logging sessions and logging period depends on user requirements.

     

    Environmental Specifications
    Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature -20 °C to +60 °C (−4 °F to 140 °F)
    Operating humidity 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH
    30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
    40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
    Operating altitude 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
    Storage altitude 12,000m
    Enclosure IP50 in accordance with EN60529
    Vibration MIL 28800E, Type 3, Class III, Style B
    Safety IEC 61010-1: Overvoltage CAT IV, Measurement 1000 V CAT III / 600 V CAT IV, Pollution Degree 2
    EMI, RFI, EMC EN 61326-1: Industrial
    Electromagnetic compatibility Applies to use in Korea only. Class A equipment (industrial broadcasting and communication equipment)
    Radio frequency emissions IEC CISPR 11: Group 1, Class A
    Temperature coefficient 0.1 x accuracy specification/°C

     

    General Specifications
    Color LCD display 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
    Warranty
    1730 and power supply Two-years (battery not included)
    Accessories One-year
    Calibration cycle Two-years
    Dimensions
    1730 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
    Power supply 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
    1730 with power supply attached 19.8 cm x 16.7 cm x 9 cm
    (7.8 in x 6.6 in x 3.5 in)
    Weight 1730 1.1 kg (2.5 lb)
    Power supply 400 g (0.9 lb)
    External protection Holster, Kensington lock slot

    1500-12 iFlex Flexible Current Probe

    Specifications
    Measuring range 1 to 150 A ac / 10 to 1500 A ac
    Nondestructive current 100 kA (50/60 Hz)
    Intrinsic error at reference condition* ± 0.7 % of reading
    Accuracy 1730 + iFlex ± (1 % of reading + 0.02 % of range)
    Temperature coefficient over operating temperature range 0.05 % of reading/°C 0.09 % of reading/°F
    Working voltage 1000 V CAT III, 600 V CAT IV
    Probe cable length 305 mm (12 in)
    Probe cable diameter 7.5 mm (0.3 in)
    Minimum bending radius 38 mm (1.5 in)
    Output cable length 2 m (6.6 ft)
    Weight 115 g
    Transducer cable material TPR
    Coupling material POM + ABS/PC
    Output cable TPR/PVC
    Operating temperature -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176°F)
    Temperature, non-operating -40 °C to +80 °C (-40 °F to 176 °F)
    Relative humidity, operating 15 % to 85 % non-condensing
    IP rating IEC 60529:IP50
    Warranty One-year
    *Reference condition:

    • Environmental: 23 °C ± 5 °C, no external electrical/magnetic field, RH 65 %
    • Primary conductor in center position