Voltage Measurement (V) Ranges Method Accuracy Input impedance 600.0V True RMS ± 0.5%rdg ± 10dgts (>30V) 2M Ω Current Measurement (A) Ranges Method Accuracy 250A 、 500A 、 1000A True RMS ± 0.5%rdg ± 10dgts+clamp on sensor specifications Active Power Measurement (KW) Ranges Accuracy Effect of power factor 600.0KW ± 0.5%rdg ± 10dgts+clamp on sensor specifications ± 0.1%rdg Reactive Power Measurement (KVAR) Ranges Accuracy Effect of power factor 600.0KVAR ± 0.5%rdg ± 10dgts+clamp on sensor ± 0.1%rdg specifications Apparent Power Measurement (KVA) Ranges Accuracy 600.0KVA ± 0.5%rdg ± 10dgts+clamp on sensor specifications Power Integration Measurement Power Integration Resolution Accuracy 0.0KWh to 9999MWh 0.1KWh ± 0.5%rdg ± 10dgts+clamp on sensor specifications 0.0Kvarh to 9999Mvarh 0.1Kvarh 0.0KVAh to 9999MVAh 0.1KVAh Power Factor Measurement Ranges Accuracy Polarity display -1.000(lead) to 0.000 to + 1.000 (lag) ± 1dgt for each calculation from measured values When the current lags the voltage unsigned ; when the current leads the voltage : “-“. Frequency Measurement Ranges Measurement source Accuracy 40Hz to 100Hz Voltage U1 ± 0.5%rdg ± 1dgt
General Specifications Size 235(L)x116(W)x54(H)mm (9.3″Lx4.6″Wx2.1″H) 0 ℃ to 50 ℃ (32 ℉ to 122 ℉ ) R.H. < 80% non-condensing Operating Temperature and Humidity – 10 ℃ to 60 ℃ (14 ℉ to 140 ℉ ) R.H. < 70% noncondensing Storage Temperature and Humidity Instruction manual , Software CD Rom / Optical RS-232 interface , Deluxe carrying case , Battery (“AA” 1.5V ′ 8pcs ) , AC adaptor (110V -> 12V ; 220V -> 12V) , 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters) (1000A AC, jaw opening 40mm) , 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)