Infrared Thermometers Fluke 566

Two-in-one IR and contact thermometers with an innovative dot matrix display.

With a simple, 3-button on-screen menu interface (in 6 languages) the Fluke 568 and 566 digital laser thermometers make even complex measurements easy. Quickly navigate advanced features to adjust emissivity, start data logging, or turn on and off alarms – with just a few pushes of a button.
With a rugged, easy-to-use, ergonomic design, the Fluke 568 and 566 two-in-one contact and non contact thermometerscan stand up to tough industrial, electrical, and mechanical environments. These tools go beyond other IR thermometers (or pyrometers), helping you work more efficiently in more applications.

    Error: Contact form not found.

    Features and benefits of the 566:

    • Measure -40°C to 800°C /-40°F to 1472°F (568) or -40°C to 650°C/-40°F to 1202°F (566)
    • Easily access advanced features with the soft-key buttons and dot-matrix display
    • Measure smaller objects from further away, with a distance-to-spot ratio of 50:1 (568) or 30:1 (566)
    • Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments
    • Confidently measure a wide variety of surfaces, with the adjustable emissivity feature, including a built-in material table
    • Capture multiple points of data (up to 99 with the 568, and 20 with the 566), for downloading and recalling later
    • Easily adapt to lighting conditions with 2 levels of backlight
    • Audible and visual alarms instantly alert you to measurements outside of your set limits
    • Quickly identify problems with the MIN, MAX, AVG, and DIF functions
    • Make contact thermometer measurements right away with the included Type-K thermocouple bead probe
    • Confidently troubleshoot equipment with 1% measurement accuracy

    Versatile interface with 6 languages from which to choose

    Product Specifications
    Infrared temperature range -40°C to 650°C (-40°F to 1202°F)
    Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
    > 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
    Display resolution 0.1°C / 0.1°F
    Infrared spectral response 8 µm to 14 µm
    Infrared response time < 500 msec
    Thermocouple Type-K input temperature range -270°C to 1372°C (-454°F to 2501°F)
    Thermocouple Type-K input accuracy -270°C to -40°C ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F))
    -40°C to 1372°C ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater
    D:S (distance to measurement spot size) 30:1
    Laser sighting Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
    Minimum spot size 19 mm (0.75 in)
    Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
    Data storage with date/time stamp 20 points
    PC interface and cable None
    Hi/Low alarms Audible and two-color visual
    Min/Max/Avg/Dif Yes
    Display Dot matrix 98 x 96 pixels with function menus
    Backlight Two levels, normal and extra bright for darker environments
    Trigger lock Yes
    Switchable Celsius and Fahrenheit Yes
    Power 2 AA/LR6 Batteries
    Battery life If used continuously Laser and backlight on, 12 hours; laser and backlight off, 100 hours
    Operating temperature 0°C to 50°C (32°F to 122°F)
    Storage temperature -20°C to 60°C (-40°F to 140°F)
    Bead thermocouple Type-K range -40°C to 260°C (-40°F to 500°F)
    Bead thermocouple Type-K accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F),
    typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)

    Download Data Sheet

    Reviews

    There are no reviews yet.

    Be the first to review “Infrared Thermometers Fluke 566”