Flue Gas Analyzer Testo-340

Compact design combined with reliable engineering makes testo 340 the ideal analyser for commissioning, service and maintenance work as well as measurements for monitoring purposes; Industrial burners, Stationary industrial engines, Gas turbines & Thermal processes.

    Error: Contact form not found.

    • Direct measurement of 4-gases simultaneously
    • CO range extension 50,000 PPM
    • Automatic sensor protection range extension
    • Smart phone App compatible
    Differential Pressure – Piezoresistive
    Measuring range -200 to 200 hPa
    Accuracy ±0.5 hPa (-49.9 to 49.9 hPa)

    ±1.5 % of mv (Remaining Range)

    Resolution 0.1 hPa
    Absolute Pressure
    Measuring range +600 to +1150 hPa
    Accuracy ±10 hPa
    Resolution 1 hPa
    Flue gas O₂
    Measuring range 0 to 25 Vol.%
    Accuracy ±0.2 Vol.%
    Resolution 0.01 Vol.%
    Reaction time t₉₀ < 20 s
    Flue gas CO (with H₂-compensation)
    Measuring range 0 to 10000 ppm
    Accuracy ±10 ppm or ±10 % of mv (0 to 200 ppm)

    ±20 ppm or ±5 % of mv (201 to 2000 ppm)

    ±10 % of mv (2001 to 10000 ppm)

    Resolution 1 ppm
    Reaction time t₉₀ < 40 s
    Flue gas COlow
    Measuring range 0 to 500 ppm
    Accuracy ±2 ppm (0 to 39.9 ppm)

    ±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K.

    Resolution 0.1 ppm
    Reaction time t₉₀ < 40 s
    Flue gas NO
    Measuring range 0 to 4000 ppm
    Accuracy ±5 ppm (0 to 99 ppm)

    ±5 % of mv (100 to 1999 ppm)

    ±10 % of mv (2000 to 4000 ppm)

    Resolution 1 ppm
    Reaction time t₉₀ < 30 s
    Flue gas Nolow
    Measuring range 0 to 300 ppm
    Accuracy ±2 ppm (0 to 39.9 ppm)

    ±5 % of mv (Remaining Range)

    Resolution 0.1 ppm
    Reaction time t₉₀ < 30 s
    Flue gas NO₂
    Measuring range 0 to 500 ppm
    Accuracy ±10 ppm (0 to 199 ppm)

    ±5 % of mv (Remaining Range)

    Resolution 0.1 ppm
    Reaction time t₉₀ < 40 s

    To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.

    Flue gas SO₂
    Measuring range 0 to 5000 ppm
    Accuracy ±10 ppm (0 to 99 ppm)

    ±10 % of mv (Remaining Range)

    Resolution 1 ppm
    Reaction time t₉₀ < 40 s

    To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.

    Flue gas Draught
    Measuring range -40 to +40 hPa
    Accuracy ±0.03 hPa (-2.99 to +2.99 hPa)

    ±1.5 % of mv (Remaining Range)

    Resolution 0.01 hPa
    Temperature
    Measuring range -40 to +1200 °C
    Accuracy ±0.5 °C (0 to +99 °C)

    ±0.5 % of mv (Remaining Range)

    Resolution 0.1 °C
    Flue gas degree of effectivity, Eta (calculated)
    Measuring range 0 to 120 %
    Resolution 0.1 %
    Flue gas loss (calculated)
    Measuring range 0 to 99.9 %
    Resolution 0.1 %
    Flue gas dewpoint (calculated)
    Measuring range 0 to 99.9 °Ctd
    Resolution 0.1 °Ctd
    Flue gas CO₂ calculation (calculated from O₂)
    Measuring range 0 to CO₂ max
    Accuracy ±0.2 Vol.%
    Resolution 0.1 Vol.%
    Reaction time t₉₀ < 40 s

     

    Download Data Sheet

    Reviews

    There are no reviews yet.